Doors, Windows, Transfer Units and Resistance against Assault

SECURITY DOORS AND WINDOWS – TESTED RESISTANCE AGAINST BREAK-IN ACCORDING TO EUROPEAN STANDARDS BY SECURITY CLASSES

Class 3 according to ČSN ENV 1627 resistance against mechanical manual tools such as longer screwdriver, pry bar, pliers, hammer, knife, tweezers, jack, wire, hook
Class 4 according to ČSN ENV 1627 estimated attack of an experienced thief, security as in Class 3 + resistance against tools such as a saw with a disk for metal, axe, heavy hammer, metal sheers, AKU electric drill
Class 5* according to ČSN ENV 1627 estimated attack of an experienced thief, security as in Class 4 + resistance against tools such as electric drill, reciprocating saw, angle grinder with a disk diameter of 125 mm at the most
Class 6* according to ČSN ENV 1627 estimated attack of an experienced thief, security as in Class 5 + resistance against tools such as angle grinder with a disk diameter of 230 mm at the most

* Security doors Class 5 and 6 according to CSN ENV 1627 correspond to safe doors Class I and II according to CSN EN 1143-1.

SECURITY WINDOWS – TESTED RESISTANCE AGAINST PERSONAL ATTACK ACCORDING TO EUROPEAN STANDARDS BY RESISTANCE CLASSES

P1A/P2A according to ČSN EN 356 glass for objects that do not store significant material values and are located under centralized or internal physical protection (food stores, restaurants, bars, administrative departments, offices, production premises); the resistance class of the product for security glazing must be increased when material values are located near shop windows and windows
P3A/P4A podle normy ČSN EN 356 glass for objects that store material values with high practical value, historical and cultural values and that are located under centralized or internal physical protection; operating theatres, banks, rooms of controlling and administrative authorities (unless the installation of bullet-proof glass is required), sales rooms of jewellery shops, gun shops, pharmacies (provided that there are no precious stones, guns and drugs there outside the business hours), museums, galleries (in the form of screens, display cases for the protection of individual exhibits in exhibition rooms)
P5A/P6B according to ČSN EN 356 glass for objects that do not store significant material values and where there is no centralized or permanent physical protection; storage spaces independent of the type of protection
P6B/P7B according to ČSN EN 356 glass for archives, museum collection storage rooms located under centralized or internal physical protection
P7B/P8B according to ČSN EN 356 glass for objects that store material values with high practical value, where there is no centralized or permanent physical protection, sales rooms of jewellery shops, gun shops, pharmacies (provided that there are precious stones, guns and drugs there outside the business hours, independent of the type of protection), bank interiors (unless the installation of bullet-proof glass is required), archives and museum collection storage rooms that do not have centralized or internal physical protection

SECURITY DOORS, WINDOWS AND TRANSFER UNITS – TESTED RESISTANCE AGAINST PENETRATION ACCORDING TO EUROPEAN STANDARDS BY RESISTANCE CLASSES

FB 1 according to ČSN EN 1522 tested resistance against rifle with calibre of 0.22LR
FB 2 according to ČSN EN 1522 tested resistance against pistol with calibre of 9 mm Luger
FB 3 according to ČSN EN 1522 tested resistance against pistol with calibre 0.357 Magnum
FB 4 podle normy ČSN EN 1522 tested resistance against pistol with calibre 0.357 Magnum and with calibre 0.44 Rem Magnum
FB 5 according to ČSN EN 1522 tested resistance against assault rifle with calibre 5.56x45
FB 6 according to ČSN EN 1522 tested combination of resistance against rifle with calibre 5.56x45 and assault rifle with calibre 7.62x51
FB 7 according to ČSN EN 1522 tested resistance against rifle with calibre 7.62x51
FSG according to ČSN EN 1522 tested resistance against shotgun with calibre CAL 12/70

BALLISTIC-RESISTANT GLASS – TESTED RESISTANCE AGAINST PENETRATION ACCORDING TO EUROPEAN STANDARDS BY RESISTANCE CLASSES

BR 1 according to ČSN EN 1063 tested resistance against rifle with calibre of 0.22LR
BR 2 according to ČSN EN 1063 tested resistance against pistol with calibre of 9 mm Luger
BR 3 according to ČSN EN 1063 tested resistance against pistol with calibre 0.357 Magnum
BR 4 according to ČSN EN 1063 tested resistance against pistol with calibre 0.44 Rem Magnum
BR 5 according to ČSN EN 1063 tested resistance against rifle with calibre 5.56x45
BR 6 according to ČSN EN 1063 tested resistance against rifle with calibre 7.62x51 (ammunition with soft core)
BR 7 according to ČSN EN 1063 tested resistance against rifle with calibre 7.62x51 (ammunition with hard core)
SG 1 according to ČSN EN 1063 tested resistance against shotgun with calibre CAL 12/70 (1 shot)
SG 2 according to ČSN EN 1063 tested resistance against shotgun with calibre CAL 12/70 (3 shots)

Classes with the NS suffix indicate ballistic-resistant glass without spray.

Discover our security doors, windows and transfer units